Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Biomedical Engineering ; (6): 320-326, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981545

RESUMO

In clinical practice, radiopharmaceutical dynamic imaging technology requires the bolus injection method to complete injection. Due to the failure rate and radiation damage of manual injection, even experienced technicians still bear a lot of psychological burden. This study combined the advantages and disadvantages of various manual injection modes to develop the radiopharmaceutical bolus injector, and explored the application of automatic injection in the field of bolus injection from four aspects: radiation protection, occlusion response, sterility of injection process and effect of bolus injection. Compared with the current mainstream manual injection method, the bolus manufactured by the radiopharmaceutical bolus injector based on the automatic hemostasis method had a narrower full width at half maximum and better repeatability. At the same time, radiopharmaceutical bolus injector had reduced the radiation dose of the technician's palm by 98.8%, and ensured more efficient vein occlusion recognition performance and sterility of the entire injection process. The radiopharmaceutical bolus injector based on automatic hemostasis has application potential in improving the effect and repeatability of bolus injection.


Assuntos
Compostos Radiofarmacêuticos , Injeções , Mãos
2.
Journal of Biomedical Engineering ; (6): 982-988, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1008924

RESUMO

Radiopharmaceutical dynamic imaging typically necessitates intravenous injection via the bolus method. However, manual bolus injection carries the risk of handling errors as well as radiological injuries. Hence, there is potential for automated injection devices to replace manual injection methods. In this study, the effect of micro-bolus pulse injection technology was compared and verified by radioactive experiments using a programmable injection pump, and the overall bubble recognition experiment and rat tail vein simulation injection verification were performed using the piezoelectric sensor preloading method. The results showed that at the same injection peak speed, the effective flushing volume of micro-bolus pulse flushing (about 83 μL/pulse) was 49.65% lower than that of uniform injection and 25.77% lower than that of manual flushing. In order to avoid the dilution effect of long pipe on the volume of liquid, the use of piezoelectric sensor for sealing preloading detection could accurately predict the bubbles of more than 100 μL in the syringe. In the simulated injection experiment of rat tail vein, when the needle was placed in different tissues by preloading 100 μL normal saline, the piezoelectric sensor fed back a large difference in pressure attenuation rate within one second, which was 2.78% in muscle, 17.28% in subcutaneous and 54.71% in vein. Micro-bolus pulse injection method and piezoelectric sensor sealing preloading method have application potential in improving the safety of radiopharmaceutical automatic bolus injection.


Assuntos
Animais , Ratos , Compostos Radiofarmacêuticos/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA